Power system models with I/O interfaces
Extends from Modelica.Icons.BasesPackage (Icon for packages containing base classes).
Name | Description |
---|---|
Figures | These models are not to be used for any purpose other than presenting figures in documentation. |
gridIO | Power grid model with input/output interfaces and modifications for simulation and linearization |
gridIOsiso | Single input single output variant of gridIO |
Tests | Test models for gridIO block |
Power grid model with input/output interfaces and modifications for simulation and linearization
Reference |
SMIB PSAT, d_kundur2.mdl, PSAT |
Last update |
June 24, 2022 |
Author |
Luigi Vanfretti |
Contact |
luigi.vanfretti@gmail.com |
Extends from Base.Networks.BasePFnFault (Partial SMIB Model with power flow data and a fault component), Example1.Interfaces.OutputsInterfaceWEfdAndAVRout.
Name | Description |
---|---|
line_1 | |
line_2 | |
pf | Specify power flow data to derive star values |
fault | |
Line Removal Parameters | |
t1 | Time of line removal [s] |
t2 | Line re-insertion time [s] |
opening | Type of opening (1: removes both ends at same time, 2: removes sending end, 3: removes receiving end) |
Fault Parameters | |
t1fault | Start time of the fault [s] |
t2fault | End time of the fault [s] |
Rfault | Resistance [1] |
Xfault | Reactance [1] |
PSS | |
Kw | Stabilizer gain (pu/pu) |
Tw | Wash-out time constant (s) |
T1 | First stabilizer time constant (s) |
T2 | Second stabilizer time constant (s) |
T3 | Third stabilizer time constant (s) |
T4 | Fourth stabilizer time constant (s) |
AVR | |
vfmax | max lim. |
vfmin | min lim. |
K0 | regulator gain |
Power Flow Scenario | |
Power Flow Data | |
replaceable record Bus | |
replaceable record Loads | |
replaceable record Trafos | |
replaceable record Machines |
Name | Description |
---|---|
Vt | |
Q | |
P | |
w | |
delta | |
AVRin | |
AVRout | |
uPSS | |
uPm | |
uPload | |
uvs | |
Power Flow Scenario | |
Power Flow Data | |
replaceable record Bus | |
replaceable record Loads | |
replaceable record Trafos | |
replaceable record Machines |
Single input single output variant of gridIO
Name | Description |
---|---|
Line Removal Parameters | |
t1 | Time of line removal [s] |
t2 | Line re-insertion time [s] |
opening | Type of opening (1: removes both ends at same time, 2: removes sending end, 3: removes receiving end) |
Power Flow Scenario | |
Power Flow Data | |
replaceable record Bus | |
replaceable record Loads | |
replaceable record Trafos | |
replaceable record Machines |
Name | Description |
---|---|
Vt | |
uvs | |
Power Flow Scenario | |
Power Flow Data | |
replaceable record Bus | |
replaceable record Loads | |
replaceable record Trafos | |
replaceable record Machines |