Example1.Base.Systems

Power system models with I/O interfaces

Information

Extends from Modelica.Icons.BasesPackage (Icon for packages containing base classes).

Package Content

Name Description
Example1.Base.Systems.Figures Figures These models are not to be used for any purpose other than presenting figures in documentation.
Example1.Base.Systems.gridIO gridIO Power grid model with input/output interfaces and modifications for simulation and linearization
Example1.Base.Systems.gridIOsiso gridIOsiso Single input single output variant of gridIO
Example1.Base.Systems.Tests Tests Test models for gridIO block

Example1.Base.Systems.gridIO Example1.Base.Systems.gridIO

Power grid model with input/output interfaces and modifications for simulation and linearization

Information

Reference

SMIB PSAT, d_kundur2.mdl, PSAT

Last update

June 24, 2022

Author

Luigi Vanfretti

Contact

luigi.vanfretti@gmail.com

Extends from Base.Networks.BasePFnFault (Partial SMIB Model with power flow data and a fault component), Example1.Interfaces.OutputsInterfaceWEfdAndAVRout.

Parameters

NameDescription
line_1 
line_2 
pfSpecify power flow data to derive star values
fault 
Line Removal Parameters
t1Time of line removal [s]
t2Line re-insertion time [s]
openingType of opening (1: removes both ends at same time, 2: removes sending end, 3: removes receiving end)
Fault Parameters
t1faultStart time of the fault [s]
t2faultEnd time of the fault [s]
RfaultResistance [1]
XfaultReactance [1]
PSS
KwStabilizer gain (pu/pu)
TwWash-out time constant (s)
T1First stabilizer time constant (s)
T2Second stabilizer time constant (s)
T3Third stabilizer time constant (s)
T4Fourth stabilizer time constant (s)
AVR
vfmaxmax lim.
vfminmin lim.
K0regulator gain
Power Flow Scenario
Power Flow Data
replaceable record Bus 
replaceable record Loads 
replaceable record Trafos 
replaceable record Machines 

Connectors

NameDescription
Vt 
Q 
P 
w 
delta 
AVRin 
AVRout 
uPSS 
uPm 
uPload 
uvs 
Power Flow Scenario
Power Flow Data
replaceable record Bus 
replaceable record Loads 
replaceable record Trafos 
replaceable record Machines 

Example1.Base.Systems.gridIOsiso Example1.Base.Systems.gridIOsiso

Single input single output variant of gridIO

Parameters

NameDescription
Line Removal Parameters
t1Time of line removal [s]
t2Line re-insertion time [s]
openingType of opening (1: removes both ends at same time, 2: removes sending end, 3: removes receiving end)
Power Flow Scenario
Power Flow Data
replaceable record Bus 
replaceable record Loads 
replaceable record Trafos 
replaceable record Machines 

Connectors

NameDescription
Vt 
uvs 
Power Flow Scenario
Power Flow Data
replaceable record Bus 
replaceable record Loads 
replaceable record Trafos 
replaceable record Machines 
Automatically generated Wed Mar 13 11:30:33 2024.